Skip to main content
  • Place orders quickly and easily
  • View orders and track your shipping status
  • Enjoy members-only rewards and discounts
  • Create and access a list of your products
  • Manage your Dell EMC sites, products, and product-level contacts using Company Administration.

Dell Storage Manager 2020 R1 Administrator's Guide

Remove CHAP Settings for a Server in an iSCSI Fault Domain

Remove CHAP settings for a server to prevent it from targeting the Storage Center while CHAP is enabled for the fault domain.

Steps

  1. If the Dell Storage Manager Client is connected to a Data Collector, select a Storage Center from the Storage view.
  2. Click the Storage tab.
  3. In the Storage tab navigation pane, expand Fault Domains, then expand iSCSI and click the fault domain.
  4. In the right pane, click Configure CHAP.
    The Configure CHAP dialog box opens.
  5. In the Remote CHAP Configuration table, select a CHAP configuration, then click Remove.
    The CHAP configuration is removed from the table.
  6. Click OK.
    The Configure CHAP dialog box closes.

Rate this content

Accurate
Useful
Easy to understand
Was this article helpful?
0/3000 characters
  Please provide ratings (1-5 stars).
  Please provide ratings (1-5 stars).
  Please provide ratings (1-5 stars).
  Please select whether the article was helpful or not.
  Comments cannot contain these special characters: <>()\