Dell Storage Manager 2020 R1 Administrator's Guide

Enable Bidirectional CHAP for iSCSI Replication in a Fault Domain

When bidirectional CHAP is enabled for iSCSI replication, the source Storage Center (initiator) challenges the destination Storage Center (target) for a shared secret.

Prerequisites

CHAP must be enabled for the fault domain.

Steps

  1. If the Dell Storage Manager Client is connected to a Data Collector, select a Storage Center from the Storage view.
  2. Click the Storage tab.
  3. In the Storage tab navigation pane, expand Fault Domains, then expand iSCSI and click the fault domain.
  4. In the right pane, click Configure CHAP.
    The Configure CHAP dialog box opens.
  5. Type a shared secret in the Bidirectional CHAP Secret field.

Rate this content