メイン コンテンツに進む
  • すばやく簡単にご注文が可能
  • 注文内容の表示、配送状況をトラック
  • 会員限定の特典や割引のご利用
  • 製品リストの作成とアクセスが可能
  • 「Company Administration(会社情報の管理)」では、お使いのDell EMCのサイトや製品、製品レベルでのコンタクト先に関する情報を管理できます。

Dell EMC SmartFabric OS10 User Guide Release 10.5.0

PDF

errdisable detect cause bpduguard

Configures the port to be shut down or moves the port to blocked state on detecting a BPDU guard violation.

Syntax
errdisable detect cause bpduguard
Parameters
None
Default
Enabled
Command Mode
CONFIGURATION
Usage Information

This command applies only to STP-enabled ports. The command takes effect only when the BPDU guard is configured on a port.

When the detect cause option is enabled, the port is shut down whenever there is a BPDU guard violation.

When the option is disabled, the port is not shut down but moved to BLOCKING state whenever there is a BPDU guard violation. In this case, the port is operationally DOWN in spanning-tree mode and when the recovery timer expires after 300 seconds, the port is UP irrespective of the recovery cause configuration.

The no version of the command disables the detect cause option.

Example
OS10(config)# errdisable detect cause bpduguard
Supported Releases
10.4.2.0 or later

このコンテンツを評価する

正確
有益
分かりやすい
この記事は役に立ちましたか?
0/3000 characters
  1~5個の星の数で評価してください。
  1~5個の星の数で評価してください。
  1~5個の星の数で評価してください。
  この記事は役に立ちましたか?
  コメントでは、以下の特殊文字は利用できません: <>()\