iscsi enable

Enables iSCSI autodetection of attached storage arrays and switch autoconfiguration.

Syntax
iscsi enable
Parameter
None
Default

None

Command Mode
CONFIGURATION
Usage Information

iSCSI optimization automatically detects storage arrays and autoconfigures switch ports with the iSCSI parameters that are received from a connected device. The no version of this command disables iSCSI autodetection.

Starting from release 10.4.1.1, when you perform a fresh installation of OS10, iSCSI autoconfig is enabled and flow control receive is set to on. However, when you upgrade from an earlier release to release 10.4.1.1 or later, the existing iSCSI configuration is retained and the flow control receive could be set to on or off, depending on the iSCSI configuration before upgrade.

Example
OS10(config)# iscsi enable
Supported Releases
10.3.0E or later