Identify the master IOM

To initiate the module replacement process, identify the master IOM connected to the SmartFabric.

To identify the master IOM in the SmartFabric, use the show smartfabric cluster member command. For more information, see show smartfabric cluster member. Run the command from any of the IOMs connected in the SmartFabric. The content displayed varies depending on the switch role.

If the command is run on a member, the system displays only the details of the master IOM. The system displays information such as service tag and IPv6 address of the master. If the command is run in a master, the system displays the details of all the IOMs in the chassis deployment. Log in to the master IOM using the displayed IPv6 address before using the module replacement command. For more information about how to log in to the master IOM from the member, see Log in to the master IOM from the member.

Also you can view the IPv4 address of the master IOM using the show smartfabric cluster command. For more information, see show smartfabric cluster.

To identify the master IOM:

View the details of the master IOM using the show smartfabric cluster member command in the EXEC mode.
MX9116N-A1# show smartfabric cluster member

Sample output

If you use the show smartfabric cluster member command on the master IOM, the system displays the following output:

MX9116N-A1# show smartfabric cluster member 
Service-tag IP Address                        Status Role   Type    Chassis-     Chassis
                                                                    Service-Tag  -Slot
----------------------------------------------------------------------------------------
HRA0024 fde1:53ba:e9a0:de14:2204:fff:fe13:143 ONLINE MASTER MX9116n ARH0006      B2

If you use the show smartfabric cluster member command on the member IOM, the system displays the following output:

MX9116N-B2# show smartfabric cluster member 
Service  IP Address                             Status Role    Type   Chassis-    Chassis
-tag                                                                  Service-Tag -Slot
------------------------------------------------------------------------------------------
HRA0015  fde1:53ba:e9a0:de14:2204:fff:fe0c:d637 ONLINE BACKUP  MX9116n  ARH0004   B1          
HRA0039  fde1:53ba:e9a0:de14:2204:fff:fe20:5249 ONLINE BACKUP  MX9116n  ARH0010   B1          
HRA0016  fde1:53ba:e9a0:de14:2204:fff:fe0c:e637 ONLINE BACKUP  MX9116n  ARH0004   B2          
HRA0035  fde1:53ba:e9a0:de14:2204:fff:fe21:7fc9 ONLINE BACKUP  MX9116n  ARH0009   B1          
HRA0008  fde1:53ba:e9a0:de14:2204:fff:fe20:7f49 ONLINE BACKUP  MX9116n  ARH0002   B2          
HRA0023  fde1:53ba:e9a0:de14:2204:fff:fe0c:f1b7 ONLINE BACKUP  MX9116n  ARH0006   B1          
HRA0031  fde1:53ba:e9a0:de14:2204:fff:fe16:d553 ONLINE BACKUP  MX9116n  ARH0008   B1          
HRA0036  fde1:53ba:e9a0:de14:2204:fff:fe20:56c9 ONLINE BACKUP  MX9116n  ARH0009   B2          
HRA0019  fde1:53ba:e9a0:de14:2204:fff:fe21:1c9  ONLINE BACKUP  MX9116n  ARH0005   B1          
HRA0017  fde1:53ba:e9a0:de14:2204:fff:fe21:9f49 ONLINE BACKUP  MX9116n  ARH0005   A1          
HRA0032  fde1:53ba:e9a0:de14:2204:fff:fe17:3bd3 ONLINE BACKUP  MX9116n  ARH0008   B2          
HRA0024  fde1:53ba:e9a0:de14:2204:fff:fe13:143  ONLINE MASTER  MX9116n  ARH0006   B2
...          