Table 1. omconfig Test Controller Alarm . The following table describes the process to test the functionality of the controller alarm.

Description

Tests the functionality of the controller alarm. The alarm sounds for about two seconds. For more information, see Dell EMC OpenManage Online Help.

Syntax

omconfig storage controller action=testalarm controller=id , where id is the controller ID as reported by the omreport storage controller command.

Example to

Test the alarm on controller 1.

Example

omconfig storage controller action=testalarm controller=1