跳转至主要内容
  • 快速、轻松地下订单
  • 查看订单并跟踪您的发货状态
  • 创建并访问您的产品列表
  • 使用“Company Administration”(公司管理),管理Dell EMC站点、产品和产品级联系人。

Dell PowerEdge FN I/O Module Command Line Reference Guide 9.10(0.0)

PDF

downstream

Assign a port or port-channel to the uplink-state group as a downstream interface.

Syntax downstream interface

To delete an uplink-state group, enter the no downstream interface command.

Parameters
interface Enter one of the following interface types:
  • 10 Gigabit Ethernet: tengigabitethernet { slot/port | slot/port-range}
  • Port channel: port-channel { 1-512 | port-channel-range}

Where port-range and port-channel-range specify a range of ports separated by a dash (-) and/or individual ports/port channels in any order; for example: tengigabitethernet 1/1-2,5,9,11-12 port-channel 1-3,5. A comma is required to separate each port and port-range entry.

Defaults none
Command Modes UPLINK-STATE-GROUP
Supported Modes Programmable-Mux (PMUX)

Full–Switch

Command History
Version Description
9.9(0.0) Introduced on the FN IOM.
9.4(0.0) Supported on the FN I/O Aggregator.
Usage Information

You can assign physical port or port-channel interfaces to an uplink-state group.

You can assign an interface to only one uplink-state group. Configure each interface assigned to an uplink-state group as either an upstream or downstream interface, but not both.

You can assign individual member ports of a port channel to the group. An uplink-state group can contain either the member ports of a port channel or the port channel itself, but not both.

Related Commands
  • upstream — assigns a port or port-channel to the uplink-state group as an upstream interface.
  • uplink-state-group — creates an uplink-state group and enables the tracking of upstream links.