Dell PowerEdge FN I/O Module Command Line Reference Guide 9.10(0.0)

PDF

tunnel flow-label

Configure the method to set the IPv6 flow label value in the outer tunnel header.

Syntax tunnel flow-label value

To return to the default value of 0, use the no tunnel flow-label value command.

Parameters
value Enter a value to set the IPv6 flow label value in the tunnel header. The range is from 0 to 1048575. The default value is 0.
Defaults 0 (Mapped original packet flow-label value to tunnel header flow-label value)
Command Modes INTERFACE TUNNEL (conf-if-tu)
Supported Modes Full–Switch
Command History
Version Description
9.9(0.0) Introduced on the FN IOM.
9.3(0.0) Introduced on the MXL 10/40GbE Switch IO Module.
Usage Information

This command is only valid for tunnel interfaces with an IPv6 outer header.