Dell PowerEdge FN I/O Module Command Line Reference Guide 9.10(0.0)

PDF

logging coredump server

Designate a server to upload core dumps.

Syntax logging coredump server { ipv4-address} username name password [ type] password
Parameters
{ ipv4-address } Enter the server IPv4 address (A.B.C.D).
name Enter a username to access the target server.
type Enter the password type:
  • Enter 0 to enter an unencrypted password.
  • Enter 7 to enter a password that has already been encrypted using a Type 7 hashing algorithm.
password Enter a password to access the target server.
Defaults Crash kernel files are uploaded to flash by default.
Command Modes CONFIGURATION
Command History
Version Description
9.9(0.0) Introduced on the FN IOM.
8.4.16.1 Introduced on the MXL 10/40GbE Switch IO Module.
Usage Information Because flash space may be limited, using this command ensures your entire crash kernel files are uploaded successfully and completely. Only a single coredump server can be configured. Configuration of a new coredump server over-writes any previously configured server.
  • NOTE: You must disable logging coredump before you designate a new server destination for your core dumps.
Related Commands logging coredump – disables the kernel coredump