跳转至主要内容
  • 快速、轻松地下订单
  • 查看订单并跟踪您的发货状态
  • 创建并访问您的产品列表
  • 使用“Company Administration”(公司管理),管理Dell EMC站点、产品和产品级联系人。

Dell PowerEdge FN I/O Module Command Line Reference Guide 9.10(0.0)

PDF

show rmon log

Display the contents of the RMON log table.

Syntax show rmon log [ index] [brief]
Parameters
index (OPTIONAL) Enter the table index number to display just that entry.
brief (OPTIONAL) Enter the keyword brief to display the RMON log table in an easy-to-read format.
Defaults none
Command Modes EXEC
Supported Modes Full–Switch
Command History
Version Description
9.9(0.0) Introduced on the FN IOM.
8.3.16.1 Introduced on the MXL 10/40GbE Switch IO Module.
Usage Information The log table has a maximum of 500 entries. If the log exceeds that maximum, the oldest log entry is purged to allow room for the new entry.
Example (Index)
Dell#show rmon log 2
                                             RMON log entry, alarm table index 2, log index 1
                                             log time: 14638 (THU AUG 12 22:10:40 2004)
                                             description: 2
                                             Dell#
                                          
Example (Brief)
Dell#show rmon log br
                                             eventIndex     description
                                             ------------------------------
                                             2              2
                                             4              4
                                             Dell#
                                          