Dell PowerEdge FN I/O Module Command Line Reference Guide 9.10(0.0)

PDF

fcf-priority

In an FCoE map, configure the priority used by a server CNA to select an upstream FCoE forwarder (FCF).

Syntax fcf—priority priority
Parameters
priority Enter the priority assigned to the switch with the FC Flex IO module NPIV proxy gateway, which appears to a downstream server CNA as an FCF. The range of FCF priority values is from 1 to 255.
Defaults 128
Command Modes FCOE MAP
Supported Modes Full–Switch
Command History
Version Description
9.9(0.0) Introduced on the FN IOM.
9.3(0.0) Introduced on the M I/O Aggregator and MXL 10/40GbE Switch with the FC Flex IO module.
Usage Information

The FCF priority you assign to the Switch with the FC Flex IO module is used by server CNAs to select an upstream FCF to use for a fabric login (FLOGI).

To remove a configured FCF priority from an FCoE map, enter the no fcf-priority command.

Related Commands

fcoe-map — creates an FCoE map which contains the parameters used in the communication between servers and a SAN fabric.

show fcoe-map — displays the Fibre Channel and FCoE configuration parameters in FCoE maps.