Dell PowerEdge FN I/O Module Command Line Reference Guide 9.10(0.0)

PDF

fc zone

Create a zone.

Syntax fc zone zonename member

To delete a zone, use the no fc zone zonename member command.

Parameters
zonename Enter the zone name.
member Enter the WWPN, port ID, or domain/port.
Command Modes ALIAS CONFIGURATION
Supported Modes Full–Switch
Command History
Version Description
9.9(0.0) Introduced on the FN IOM.
9.7(0.0) Introduced on the MXL 10/40GbE Switch IO Module.
9.1(1.0) Introduced on the S5000.
Example without member
Dell(conf)# fc zone z1
                                             Dell(conf-fc-zone-z1)#
                                             
                                          
Example with member
Dell(conf)#fc zone  test
                                             Dell(conf-fc-zone-test)#member ?
                                             WORD                    WWN(00:00:00:00:00:00:00:00), portID(000000), or Alias name(word)
                                             Dell(conf-fc-zone-test)#member
                                          
Related Commands

show fc zone — displays the configured zone.

show fcoe-map — displays the fabric parameters.