Dell PowerEdge FN I/O Module Command Line Reference Guide 9.10(0.0)

PDF

show ipv6 mld_host

Display the IPv6 MLD host counters.

Syntax show ipv6 mld_host
Command Modes EXEC
Supported Modes Full–Switch
Command History
Version Description
9.9(0.0) Introduced on the FN IOM.
9.2(0.0) Introduced on the MXL 10/40GbE Switch IO Module.
Usage Information The following describes the show ipv6 mld-host command shown in the following example.
Field Description
Valid MLD Packets The total number of packets received and sent from the last time the elapsed time was cleared.
Reports The total number of reports (queries and unsolicited reports generated from joins or leaves) that have been received or sent.
Leaves The number of Multicast leaves that have been sent.
MLDv1 queries The number of MLDv1 queries that have been received.
MLDv2 queries The number of MLDv2 queries that have been received.
Malformed Packets The number of MLDv1 and MLDv2 packets that do not match the requirement for a valid MLD packet.
Example
MLD Host Traffic Counters
                                             Elapsed time since counters cleared: 0028:33:52
                                             Received   Sent
                                             Valid MLD Packets  97962      18036
                                             Reports            79962      18034
                                             Leaves             ----       0
                                             MLDv2 Queries      18000      ----
                                             MLDv1 Queries      0          ----
                                             Errors:
                                             Malformed Packets: 4510
                                          