跳转至主要内容
  • 快速、轻松地下订单
  • 查看订单并跟踪您的发货状态
  • 创建并访问您的产品列表
  • 使用“Company Administration”(公司管理),管理Dell EMC站点、产品和产品级联系人。

Dell PowerEdge FN I/O Module Command Line Reference Guide 9.10(0.0)

PDF

fcoe-map

Create an FCoE map which contains the parameters used to configure the links between server CNAs and a SAN fabric. Apply the FCoE map on a server-facing Ethernet port.

Syntax fcoe-map map-name
Parameters
map-name Maximum: 32 alphanumeric characters.
Defaults On the FN2210S Aggregator with PMUX modules, the following parameters are applied on all the PMUX module interfaces:
  • Description: SAN_FABRIC

  • Fabric-id: 1002

  • Fcoe-vlan: 1002

  • Fc-map: 0x0efc00

  • Fcf-priority: 128

  • Fka-adv-period: 8000mSec

  • Keepalive: enable

  • Vlan priority: 3

Command Modes CONFIGURATION

INTERFACE

Supported Modes Programmable-Mux (PMUX)

Full–Switch

Command History
Version Description
9.9(0.0) Introduced on the FN IOM.
9.6(0.0) Supported on the FN2210S Aggregator.
9.3(0.0) Introduced on the M I/O Aggregator.
Usage Information

An FCoE map is a template used to map FCoE and FC parameters in a converged fabric. An FCoE map is used to virtualize upstream FC ports on an FN2210S Aggregator with the PMUX module NPIV proxy gateway so that they appear to downstream server CNA ports as FCoE forwarder (FCF) ports on an FCoE network. When applied to FC and Ethernet ports on an NPIV proxy gateway, an FCoE map allows the switch to operate as an FCoE-FC bridge between an FC SAN and an FCoE network by providing FCoE-enabled servers and switches with the necessary parameters to log in to a SAN fabric.

On an FN2210S Aggregator a with the PMUX module NPIV proxy gateway, you cannot apply an FCoE map applied on fabric-facing FC ports and server-facing 10–Gigabit Ethernet ports.

An FCoE map consists of the following parameters: the dedicated FCoE VLAN used for storage traffic, the destination SAN fabric (FC-MAP value), FCF priority used by a server, and the FIP keepalive (FKA) advertisement timeout.

In each FCoE map, the fabric ID, FC-MAP value, and FCoE VLAN parameters must be unique. Use one FCoE map to access one SAN fabric. You cannot use the same FCoE map to access different fabrics.

To remove an FCoE map from an Ethernet interface, enter the no fcoe-map map-name command in Interface configuration mode.


对此内容评级

准确性
有用性
易理解性
这篇文章对您有帮助吗?
0/3000 characters
  请提供评级(1-5星)。
  请提供评级(1-5星)。
  请提供评级(1-5星)。
  请选择这篇文章是否有帮助。
  注释中不得包含以下特殊字符:<>()\