Dell PowerEdge FN I/O Module Command Line Reference Guide 9.10(0.0)

PDF

show vlan private-vlan mapping

Display primary-secondary VLAN mapping.

Syntax show vlan private-vlan mapping
Defaults none
Command Modes
  • EXEC
  • EXEC Privilege
Supported Modes Full—Switch
Command History
Version Description
9.9(0.0) Introduced on the FN IOM.
8.3.16.1 Introduced the on MXL 10/40GbE Switch IO Module.
Usage Information

The output of this command, shown below, displays the community and isolated VLAN IDs that are associated with each primary VLAN.

Example
Dell# show vlan private-vlan mapping
                                             Private Vlan:
                                             Primary   : 100
                                             Isolated  : 102
                                             Community : 101
                                             Unknown   : 200
                                          
Related Commands

private-vlan mode — sets the mode of the selected VLAN to community, isolated, or primary.

show vlan private-vlan — displays type and status of PVLAN interfaces.

show vlan private-vlan mapping — displays the primary-secondary VLAN mapping.

switchport mode private-vlan — sets PVLAN mode of the selected port.