跳转至主要内容
  • 快速、轻松地下订单
  • 查看订单并跟踪您的发货状态
  • 创建并访问您的产品列表
  • 使用“Company Administration”(公司管理),管理Dell EMC站点、产品和产品级联系人。

Dell PowerEdge FN I/O Module Command Line Reference Guide 9.10(0.0)

PDF

max-hops

Configure the maximum hop count.

Syntax max-hops number

To return to the default values, use the no max-hops command.

Parameters
range Enter a number for the maximum hop count. The range is from 1 to 40. The default is 20.
Defaults 20 hops
Command Modes MULTIPLE SPANNING TREE
Supported Modes Full–Switch
Command History
Version Description
9.9(0.0) Introduced on the FN IOM.
8.3.16.1 Introduced on the MXL 10/40GbE Switch IO Module.
Usage Information The max-hops command is a configuration command that applies to both the IST and all MST instances in the MSTP region. The BPDUs sent out by the root switch set the remaining-hops parameter to the configured value of max-hops. When a switch receives the BPDU, it decrements the received value of the remaining hops and uses the resulting value as remaining-hops in the BPDUs. If the remaining-hops reach zero, the switch discards the BPDU and ages out any information that it holds for the port.