跳转至主要内容
  • 快速、轻松地下订单
  • 查看订单并跟踪您的发货状态
  • 创建并访问您的产品列表
  • 使用“Company Administration”(公司管理),管理Dell EMC站点、产品和产品级联系人。

Dell PowerEdge FN I/O Module Command Line Reference Guide 9.10(0.0)

PDF

rmon collection statistics

Enable RMON MIB statistics collection on an interface.

Syntax rmon collection statistics {controlEntry integer} [owner name]

To remove RMON MIB statistics collection on an interface, use the no rmon collection statistics {controlEntry integer} command.

Parameters
controlEntry integer Enter the keyword controlEntry to specify the RMON group of statistics using a value. Then enter an integer value from 1 to 65535 that identifies the RMON Statistic Table. The integer value must be a unique in the RMON statistic table.
owner name (OPTIONAL) Enter the keyword owner then the owner name to record the owner of the RMON group of statistics.
Defaults none
Command Modes CONFIGURATION INTERFACE (config-if)
Supported Modes Full–Switch
Command History
Version Description
9.9(0.0) Introduced on the FN IOM.
8.3.16.1 Introduced on the MXL 10/40GbE Switch IO Module.